Understanding the conversion between tons of refrigeration and kilowatts is essential for HVAC professionals. This calculation ensures accurate system sizing and energy efficiency.

This article explores the ASHRAE standard for tons of refrigeration to kilowatts conversion. It includes formulas, tables, and real-world examples for practical application.

Artificial Intelligence (AI) Calculator for “Tons of Refrigeration ↔ kW Calculator (ASHRAE)”

  • ¡Hola! ¿En qué cálculo, conversión o pregunta puedo ayudarte?
Pensando ...
  • Convert 5 tons of refrigeration to kilowatts
  • Calculate kW for 12 TR system
  • Find tons of refrigeration for 50 kW load
  • Determine kW equivalent of 3.5 TR

Comprehensive Tables for Tons of Refrigeration to Kilowatts Conversion (ASHRAE)

The following tables provide a detailed reference for converting tons of refrigeration (TR) to kilowatts (kW) based on the ASHRAE standard. These values are critical for HVAC design, energy analysis, and equipment specification.

Tons of Refrigeration (TR)Cooling Capacity (kW)Cooling Capacity (BTU/hr)Approximate Power Input (kW)
13.51712,0001.0 – 1.5 (varies by COP)
27.03424,0002.0 – 3.0
517.58560,0005.0 – 7.5
1035.170120,00010.0 – 15.0
2070.340240,00020.0 – 30.0
50175.850600,00050.0 – 75.0
100351.7001,200,000100.0 – 150.0

Note: The power input range depends on the Coefficient of Performance (COP) of the refrigeration system, which varies by technology and operating conditions.

Fundamental Formulas for Tons of Refrigeration to Kilowatts Conversion (ASHRAE)

Accurate conversion between tons of refrigeration and kilowatts requires understanding the underlying physical principles and standard definitions. The following formulas are essential for HVAC engineers and energy analysts.

1. Basic Conversion Formula

The ton of refrigeration is defined as the heat absorption rate required to freeze 1 ton (2000 lbs) of water at 0°C in 24 hours. This corresponds to a specific power value in kilowatts.

1 TR = 12,000 BTU/hr = 3.517 kW

Therefore, the general conversion formulas are:

kW = TR × 3.517
TR = kW ÷ 3.517

Explanation of Variables:

  • TR: Tons of Refrigeration, a unit of cooling capacity.
  • kW: Kilowatts, a unit of power representing the rate of energy transfer.

2. Conversion Using BTU/hr

Since 1 TR equals 12,000 BTU/hr, and 1 kW equals 3412.142 BTU/hr, the conversion can also be expressed as:

kW = (TR × 12,000) ÷ 3412.142

This formula is useful when working with BTU/hr values directly.

3. Power Input Estimation Based on Coefficient of Performance (COP)

The actual electrical power input to a refrigeration system depends on its efficiency, expressed as the Coefficient of Performance (COP). COP is the ratio of cooling capacity to power input.

Power Input (kW) = Cooling Capacity (kW) ÷ COP

Where:

  • COP: Typically ranges from 2.5 to 6 for modern systems, depending on technology and conditions.
  • Cooling Capacity (kW): Calculated from TR as above.

4. Relationship Between COP and Energy Efficiency Ratio (EER)

Energy Efficiency Ratio (EER) is another common metric, defined as cooling capacity in BTU/hr divided by power input in Watts.

COP = EER ÷ 3.412

This relationship allows conversion between EER and COP for performance analysis.

Real-World Application Examples of Tons of Refrigeration ↔ kW Conversion

Applying these formulas in practical scenarios is crucial for HVAC system design, energy audits, and equipment selection. Below are two detailed examples demonstrating step-by-step calculations.

Example 1: Converting 15 Tons of Refrigeration to Kilowatts

A commercial building requires a cooling system rated at 15 TR. Determine the equivalent cooling capacity in kilowatts and estimate the electrical power input assuming a COP of 4.0.

Step 1: Convert TR to kW

kW = TR × 3.517 = 15 × 3.517 = 52.755 kW

Step 2: Calculate Power Input Using COP

Power Input = Cooling Capacity ÷ COP = 52.755 ÷ 4.0 = 13.189 kW

Interpretation: The system provides 52.755 kW of cooling capacity, consuming approximately 13.19 kW of electrical power.

Example 2: Determining Tons of Refrigeration from a 100 kW Cooling Load

An industrial process requires a cooling load of 100 kW. Calculate the equivalent tons of refrigeration and estimate the power input if the system has an EER of 10.

Step 1: Convert kW to TR

TR = kW ÷ 3.517 = 100 ÷ 3.517 ≈ 28.44 TR

Step 2: Convert EER to COP

COP = EER ÷ 3.412 = 10 ÷ 3.412 ≈ 2.93

Step 3: Calculate Power Input

Power Input = Cooling Capacity ÷ COP = 100 ÷ 2.93 ≈ 34.13 kW

Interpretation: The cooling load corresponds to approximately 28.44 TR, with an electrical power input of about 34.13 kW.

Additional Technical Insights and Considerations

While the basic conversion between tons of refrigeration and kilowatts is straightforward, several factors influence the practical application of these calculations in HVAC engineering.

  • System Efficiency Variability: COP and EER values depend on equipment type, refrigerant, operating conditions, and maintenance.
  • Temperature Differences: The standard definition assumes freezing water at 0°C; actual cooling loads may vary with temperature and humidity.
  • Part-Load Performance: Real systems often operate below full load, affecting power consumption and efficiency.
  • Energy Codes and Standards: Compliance with ASHRAE 90.1 and other regulations requires accurate load and power calculations.
  • Measurement Units: Consistency in units (SI vs. Imperial) is critical to avoid errors in design and analysis.

For further reading and official standards, consult the ASHRAE Standards and Guidelines and the U.S. Department of Energy Energy Efficiency Resources.

Summary of Key Points for SEO Optimization

  • 1 ton of refrigeration equals exactly 3.517 kW according to ASHRAE standards.
  • Conversion formulas are essential for HVAC system design and energy analysis.
  • Power input depends on system efficiency, expressed as COP or EER.
  • Tables provide quick reference for common TR to kW values and power input ranges.
  • Real-world examples demonstrate practical application of conversion formulas.
  • Understanding these conversions supports compliance with energy codes and improves system performance.